EWP - Electric Water Pump & Fan Digital Controller Kit

SKU:
EWP8002
€195.00
Incl. 21% Tax
  • Free shipping on orders over 100 euro in NL / BE / DE

  • Professional advice

  • Physical 1000 m2 showroom

Details

ELECTRIC WATER PUMP (EWP®) & FAN DIGITAL CONTROLLER KIT

Provides optimum control of Davies, Craig 12 / 24 Volt Electric Water Pumps and Electric Fans. Suits EWP®80, EWP®115, EWP®130, EWP®150, Thermatic® / Electric Fans and billeted style Electric Water Pumps.

The controller offers enhanced appearance, slimmer and the seven-pin plug is safely tucked away, out of sight at the base of the Controller. It has 2 mounting options:
  • Bracket
  • Nylon Plate
  • The EWP®/Fan Digital Controller has two specific functions:

    Will manage the operation of the EWP® by varying the speed of the pump in response to the coolant temperature

    Manage control of your electric engine fan.

    The Controller has a push-button to lock in any temperature from 40°C (104°F) to 110°C (230°F). It’s recommended you set/target the Controller to closely match your engine’s existing thermostat temperature. The Digital Controller will operate the engine’s electric fan automatically once the engine has reached +3°C (+5.4°F) above the targeted / set temperature. Another significant benefit is that the Controller allows the EWP® & Fan to run on after ignition shutdown for either 3 minutes or -10°C (-14°F) of set set / target temperature to eliminate heat soak.

    Sensor Wire Length: 250cm, Increase to 380cm (Oct 2020)

    EWP®, Fan & LCD Controller Installation

    LCD Controller Wiring Instructions

    Kit Contents
    ITEMDESCRIPTIONUNITS
    1EWP® Digital Controller Assembly1
    2Wiring Harness (includes 10AMP fuse)1
    3Temp Sensor 1/4 NPT1
    4In-Line Adaptor (35mm ends - hose size fitting)1
    5Hose Clamps2
    6Ring Terminal1
    7Rubber Sleeves 3mm (Increase In-Line Adaptor to fit hose size 38mm)

    *For larger hose size, you will need 6mm sleeves (Part #18511) which will increase adaptor to fit hose size 41~42mm *not in kit*

    2
    8Mounting Options: Nylon Plate, Bracket3
    9Instructions1
    10Sensor Instructions1
    Technical Specification
    Voltage range12V DC to 29V DC
    Display LCD size64.6mm (2.54”) x 55.6mm (2.19”)
    Maximum current12Amps
    Warning alarmHigh & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit
    Targeted (set) temperaturesSingular degrees from:

    40°C (104°F) to 110°C (230°F)

    MemorySet & targeted temperature
    Fan cut-in temp.3°C (5.4°F) above the targeted (set) temperature
    Controller typePCB with micro-processor
    Sensor typeThermister in housing
    Overrun/ shutdown-10°C (14°F) below set/target temperature or 3 minutes
    IndicatorsTemperature, power, EWP®, test, fan, high & low temp, voltage, above set temperature (with alarm)
    Weight135 grams
    Dimensions

    Length = 98mm (3.8")

    Width = 95mm (3.7")

    Depth = 25mm (1”)

    The contrasting black & white screen and comprehensive diagnostic menu of engine cooling management at a glance includes;

  • Numerical LCD exhibiting real-time numerical on-going engine & targeted/set temperatures
  • Flashing EWP® logo signifying pump pulse, width, modulation (PWM) operation and delivering the desired coolant flow through the engine
  • Individual, adjustable targeted/set temperatures from 40°C (104°F) to 110°C (230°F)
  • Rotating Davies Craig Thermatic® Fan symbol indicating fan operation (which automatically engages at +3ºC (+37.4ºF) abovethe set/targeted coolant temperature.)
  • Your set/targeted temperature can now be held in memory if the battery is disconnected.
  • Override feature to assist with EWP® bleeding operation.
  • Voltage output.
  • A suite of self-diagnostic ‘test’ functions are still on offer that identify and deliver visual and audible warnings enabling simple trouble-shooting if a system problem is evident. An audible alarm will sound when;

  • * Coolant temperature doesn’t exceed 40ºC (104ºF) within 5 mins of start-up.
  • * Coolant exceeds +10ºC (+50ºF) of set/targeted temperature.
  • * Coolant temperature exceeds 100ºC (212ºF).
  • * Voltage supply is either too high or too low.
  • * EWP error.
  • * Temperature Sensor error.

  • Technical specifications

    Technical specifications
    Manufacturer EWP